KEITHLEY 2612A LABVIEW DRIVER DOWNLOAD

Post Your Answer Discard By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of service , privacy policy and cookie policy , and that your continued use of the website is subject to these policies. As I mentioned in the opening post, the program properly controls the source meter while running on the original computer, but it cannot find the device when it is compiled and run on a different computer see attached graphic. Sign up using Email and Password. How can I add a knob on the system so that I can choose which buffer element to print according to th value of the knob? You should try to use a delay in your while loop where you continuously read the value of bit 1. Email Required, but never shown. WG- 1 9

Uploader: Faum
Date Added: 22 May 2004
File Size: 22.40 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 88485
Price: Free* [*Free Regsitration Required]

I downloaded and installed the package that includes NI MAX and ran it, and found that the serial ports don’t even show up. Post as a guest Name.

Auto-suggest helps you keothley narrow down your search results by suggesting possible matches as you type. By clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy kithley cookie policyand that your continued use of the website is subject to these policies.

Keithhley clicking “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies.

Thank you very much for the tip! Stack Overflow works best with JavaScript enabled. The program itself runs, and the device is recognized in the Device Manager on the new computer, but the compiled program doesn’t recognize that there is even a serial port device at all!

Related Drivers  AOC 2036S MONITOR DRIVERS FOR WINDOWS 7

I tried doing it with loop tunnels their values remain constant. But only on the computer that the program was written.

Post Your Answer Discard By labviw “Post Your Answer”, you acknowledge that you have read our updated terms of serviceprivacy policy and cookie policyand that your continued use of the website is subject to these policies.

By using our site, you acknowledge that you have read and understand our Cookie PolicyPrivacy Policyand our Terms of Service.

Chris 85 1 6. As you can see in the second image, COM3 is recognized as available and allocated by the Device Manager.

keithley a interfacing with pc using labview – Discussion Forums – National Instruments

Is it possible to put the stop button and knob outside the while loop and still get the new value whenever the knob rotates or the button is pressed? A loop and a subVI have the same run-time constraints — values on their input terminals cannot change labivew they are executing. Did you try debugging your code step by step? Currently I am just experimenting with the scripting language, which the instrument uses. That might just be it! Sign up using Email and Password.

Tektronix and Keithley

LabVIEW searches for that string and replaces it with the knob’s current value. Update on specific hardware and snapshots of problem will be uploaded as soon as I get them.

To build a stand-alone program, 2621a there a place in the build options window that I need to specify these sub-vi’s? Yes, you will need to “write” the control to the instrument using SCPI commands defined in documentation for the instrument. The program includes vi’s provided by the manufacturer.

Related Drivers  A7S266-VM U2 DRIVER DOWNLOAD

Most Active Hardware Boards: You add the keithleu control, wire the value to the number-to-string VI http: Message 3 of 5. I load a script on keithley a and then I want labview to wait until the instrument has finished running the script. How can I add a knob on the system so that I can choose which buffer element to print according to th value of the knob?

Value of Numeric control in script, LabView – Stack Overflow

If you are suspecting a timeout error, why don’t you have a closer look at the error terminal of your keithley vi? Email Required, but never shown. Sign up or log in Sign up using Google. I figured I just needed the RTE to make it run You should try kejthley use a delay in your while loop where you continuously read the value of bit 1. Goes to show how new I am at this I’m downloading the VISA installer right now, and will post an update once it’s installed.

WG- I edited the question adding the script and captures from the front panel and block diagram.